have the following text above the image. “With the permission of Canadian Standards Association, material is reproduced from CSA Standard CAN/CSA -B651 -95 (R2001), Barrier-Free Design, which is copyrighted by Canadian Standards Association, 178 Rexdale Blvd., Toronto, Ontario, M9W 1R3. While use of this material has been authorized CSA shall not be responsible for the manner in which the information is Presented, nor for any interpretation thereof.” The Canadian Standards Association has given permission to use these illustrations and more information about the CSA may be found on their web site www.csa.ca |
| Hospitality Accessibility Checklist | |||||||
| Interior Areas | |||||||
| No. | Question | Yes | No | N/A | Comments | Alternative Strategies | |
| B.1 | Entrances | ||||||
| B.1.1 | Is the main accessible entrance
protected by a canopy or other sheltering device? |
||||||
| B.1.2 | Where overhead projections are
present, is the clear headroom at least 6'-8" (2030mm)? |
||||||
| B.1.3 | Are the main (public) entrance
doors accessible to persons in wheelchairs or scooters? |
||||||
| B.1.4 | Where there is a large revolving
door, are the door openings large (min. 3'-6" wide) enough to safely
accommodate persons with various disabilities or mobility aids? |
||||||
| B.1.5 | Where large revolving doors are
provided, do they move slowly enough to allow safe movement of persons with
various disabilities (or using mobility aids)? |
||||||
| B.1.6 | Where revolving entrance doors
are not large enough for wheelchair movement, has an adjacent accessible
door been provided? |
||||||
| B.1.7 | Are each of the accessible entrance
door(s) at least 2'-8" (810mm) wide between door stops? |
||||||
| B.1.8 | Do the entrance doors open automatically?
|
||||||
| B.1.9 | Where the entrance doors do not
open automatically, are the accessible entrance doors easy to open with
one hand? |
Power assisted door operators | |||||
| B.1.10* | Where accessible entrance doors
and related vestibule doors are in series, have power assisted door operators,
or automatic door openers been provided on both sets of doors? |
||||||
| B.1.11 | Is the power assisted door control
located away from the door swing or on a post, mounted between 3'-0"
and 3'-6" (915mm and 1065mm) from the floor? |
||||||
| B.1.12* | Do door closer timers provide
3 sec or more time to allow passage through the opening? |
Provide a doorman to assist disabled guests | |||||
| B.1.13* | Where there are enclosed vestibules,
is there at least 7'-0" (2135 mm) clear space between sets of doors?
|
||||||
| B.1.14 | In vestibules, are mats level
with the floor so they do not create a tripping hazard? |
Obtain mats with beveled edges | |||||
| B.1.15 | Is the door hardware on accessible
entry doors easy to grasp and use? (i.e. of the lever handle type or 'D'
Pull type)? |
||||||
| B.1.16 | Are door thresholds bevelled and
no higher than ½" (13mm), to minimize tripping hazards? |
||||||
| B.1.17* | Where doors open towards the person
approaching, is there a sufficient level paving or floor area of 5'-0"
by 5'-0" (1525mm by 1525mm) to allow a person using a wheelchair, or
a guide dog to wait safely clear of the door swing? |
||||||
| B.1.18* | Where the entrance doors, and/or
adjacent panels, are fully glazed, have bright decals or an opaque/coloured
strip been mounted at eye level, between 4'-6" and 5'-0" (1370mm
and 1525mm) as a warning to persons with visual limitations? |
||||||
| B.1.19 | From the entrance, can the entering
person see and get to an information or reception counter easily? |
||||||
| B.1.20 | Where the reception or information
desk is not visible from the entrance, is there an accessible call bell
or information phone for persons requiring assistance? |
||||||
| B.1.21 | Do all accessible entrances and
vestibules have external lighting levels of at least 10 ft candles (100
lux) measured at grade level? |
||||||
| B.1.22 | Does the accessible entrance provide
easy access to all other floors or areas of the building? |
||||||
| B.2 | Lobby and Waiting Areas | |
|||||
| B.2.1 | Are floor finishes in accessible paths of travel non-slip*: | Refinish slippery surfaces with
a non-slip, matte sealer; Provide non-slip mats or carpeting in areas that
are within 20'-0" of the main entrance doors. |
|||||
| a) under wet conditions (winter
months, times when water is sure to be tracked in)? |
|||||||
| b) under dry conditions (when
water is not being tracked in)? |
|||||||
| *NOTE: Non-slip materials should
ideally meet ASTM requirements (0.50 or better). |
|||||||
| B.2.2 | Have accessible routes across
wide open or ambiguous spaces been clearly marked by bright colour or textural
changes at floor level, to provide directional cues for persons with visual
limitations? |
||||||
| B.2.3* | Are all routes in the main lobby
free from protruding objects? |
||||||
| B.2.4 | Where there are potential tripping
hazards or items projecting into accessible routes, are they clearly marked
with a bright colour, a cane detectable floor finish, or a guard? |
||||||
| B.2.5 | Is there accessible seating for
patrons in the lobby area? (i.e. seating with firm back and arm rests) |
||||||
| B.2.6* | Are all interior routes or corridors
to all public areas of the building at least 3'-6" (1065mm) wide? |
||||||
| B.2.7 | In multi-storey buildings, is
there an easily identifiable route from the main accessible entrance to
an elevator providing access to the other floor(s)? |
||||||
| B.3 | Reception/Information/Coat Check Counters, etc. | |
|||||
| B.3.1* | Has at least 2'-8" by 4'-0"
(810mm by 1220mm) clear floor space been provided in front of all reception
counters, coat check counters or cash register locations? |
||||||
| B.3.2* | Do information, registration or
other service counters have at least one section suitable for use by patrons
using wheelchairs, (i.e. no higher than 2'-10" (865 mm) and no less
than 2'-6" (760 mm) wide), with suitable knee space below? |
Available clipboard at lowered height; Separate lowered table or desk. | |||||
| B.3.3 | Are all counters or desk tops
used by guests in a contrasting colour or tone from surrounding floors and
walls, so that they are easy to locate? |
||||||
| B.3.4 | Is at least 10 ft. candles (100
lux) of lighting provided at desks or counter tops for persons who have
visual limitations? |
||||||
| B.4 | Passenger Elevators and Lifts | |
|||||
| B.4.1 | Are elevator doorways at least
3'-6" (1065 mm) wide to allow persons using wheelchairs to pass through
easily? |
||||||
| B.4.2 | Do elevator doors stay open a
minimum of 5 seconds to allow safe passage through the opening? |
||||||
| B.4.3 | Are elevators equipped with door
sensors to prevent potential accidents? |
||||||
| B.4.4* | Where elevators are provided,
are the cabs large enough to accommodate at least one person using a wheelchair
or scooter (i.e. a minimum 5'-6" by 4'-0" (1675mm by 1220mm) clear
floor area? |
||||||
| B.4.5* | In accessible elevators, are all
controls (including elevator call buttons in lobbies) mounted no higher
than 4'-0" (1220mm) and no lower than 2'-0" (610mm) from the floor?
|
||||||
| B.4.6 | In accessible elevators, has a two way emergency call system or telephone been provided, mounted between 2'-0" and 4'-0" (610mm to 1220mm) from the floor? | ||||||
| B.4.7 | Has Braille signage been provided
beside all buttons and controls in all elevator cabs, as an aid to persons
who are visually impaired? |
||||||
| B.4.8* | Have raised numbers and Braille
information been located at eye level on door jambs of all elevator doors
to identify each floor level? |
||||||
| B.4.9 | Are there audible signals in the
elevator cabs and the elevator lobbies to alert patrons when the elevator
cab is arriving at a specific floor? |
||||||
| B.4.10 | Are the audible signals provided
in elevator lobbies to signal up and down movement different from each other?
|
||||||
| B.4.11 | Are the audible signals loud enough
to be heard above ambient noise levels? |
Reduce the volume of music or other P/A messages in the elevator cabs and lobbies. | |||||
| B.4.12 | Where passenger elevators are
provided can they be operated without the assistance of security or maintenance
personnel? |
||||||
| B.4.13 | Where stair/platform lifts are
provided (and are key-operated), is there a call bell or information phone
provided to allow persons to call for assistance? |
||||||
| B.5 | Interior Corridors and Doors | |
|||||
| B.5.1 | Where interior routes are long
and less than 5'-0" (1525 mm) wide, have turning or lay-by spaces at
least 5'-3" wide by 5'-3" long (1600mm by 1600mm) minimum been
provided at 30'-0" (9145mm) intervals? |
||||||
| B.5.2 | Is the lay-out of corridors and
spaces easy to understand and follow? (i.e. no unexpected curves or corners
other than those at 90º angles). |
Remove obstacles (seats, planters)
at changes of direction, to allow blind persons to use the walls to identify
changes. |
|||||
| B.5.3 | Are all interior pedestrian routes
well maintained and kept free of obstructions? |
||||||
| B.5.4 | Is furniture placed to one side
of normally used paths of travel, to ensure easy passage for persons using
mobility aids? |
||||||
| B.5.5 | Where columns, drinking fountains,
heating cabinets, or other objects protrude into the accessible route, is
the clear remaining passageway no less than 3'-0" (915mm) wide, for
no more than 2'-6" (760mm)? |
||||||
| B.5.6* | Where objects (e.g. telephones,
drinking fountains or other projections) occur in active corridors and aisles,
does the bottom edge protrude no more than 4" (100mm) between the heights
of 2'-2" (660mm) and 6'-8" (2030mm) from the floor? |
||||||
| B.5.7* | Where objects protrude more than
4" (100mm) into pedestrian paths, is the object: |
||||||
| a) cane detectable (i.e. mounted
with portions below 2'-2" (660mm) from the floor) |
|||||||
| b) adequately protected by defined
barriers or detectable floor finishes? |
|||||||
| B.5.8* | Is the headroom in all accessible
interior routes at least 6'-8" (2030mm) high including under stairs
or ramps? |
||||||
| B.5.9 | Are all doors, doorways or gates
from main interior corridors to adjacent rooms, or spaces at least 2'-8"
(810mm) wide between door jambs? |
||||||
| B.5.10 | Where door swings project into
active passageways, is there sufficient clear space for persons in wheelchairs
to pass by safely? (e.g. min 3'-6" (1065mm)) |
||||||
| B.5.11 | Where different flooring materials
occur, (e.g. at doorways) have all differences in level been covered with
suitable bevelled thresholds? |
||||||
| B.6 | Suite Doors and Public Doorways | |
|||||
| B.6.1 | Are all normally used doors (including
suite doors) in public areas fitted with easy to use pulls, pushes, or lever
handled hardware? |
||||||
| B.6.2 | Is all door hardware mounted between
2'-6" and 3'-6" (760mm and 1065mm) from the floor? |
||||||
| B.6.3 | Are all accessible suite door
locks mounted between 3'-0" (915mm) and 4'-0" (1220mm) from the
floor? |
||||||
| B.6.4 | Are all suite door locking devices
(including security cards), easy to use by persons with limited manual dexterity
or visual limitations? |
||||||
| B.6.5 | Is an additional peep hole provided
in each accessible suite entrance door, mounted no higher than 3'-10"
(1170mm) from the floor? |
||||||
| B.6.6 | In accessible suites and frequently
used public areas where interior doors are heavy or difficult to use (e.g.:
because of door closers), have power assisted doors been provided? |
||||||
| B.6.7 | Where power assisted doors are
provided, are the operating mechanisms: |
||||||
| a) located within easy reach of
persons using wheelchairs? |
|||||||
| b) located out of the path of
the door swing? |
|||||||
| B.6.8 | Are the thresholds at all interior
doorways no higher than ½" (13 mm) and bevelled to allow wheelchairs
to roll over them easily? |
||||||
| B.6.9 | Where balconies are provided,
are the doors to the balconies wide enough for wheelchair movement (i.e.
minimum 2'-8" (810mm) wide between door jambs)? |
||||||
| B.6.10 | Where balcony doors are accessible
is the threshold at the doorway no more than ¾" (19mm) and bevelled
to allow easy wheelchair movement? |
||||||
| B.7 | Suite Interior - Bedroom, Sitting & Dining Rooms | |
|||||
| B.7.1 | Are the following proportions of accessible guest rooms for persons using wheelchairs provided: | ||||||
| a) 1 accessible room for every
25 rooms up to 100 rooms? |
|||||||
| b) 2% of all rooms above 100 rooms?
|
|||||||
| B.7.2 | In addition to the wheelchair
accessible rooms/suites, do the following proportions of all guest rooms
include features for persons with a hearing loss? (e.g. telephones with
volume control and flashing lights) |
||||||
| a) 1 room for every 25 rooms up
to 100 rooms? |
|||||||
| b) 2% of all rooms above 100 rooms?
|
|||||||
| B.7.3 | Are accessible rooms or suites
located on various floors of the building and offered in various price ranges?
|
||||||
| B.7.4 | Are accessible suites located
near an elevator lobby or a suitable safe holding area, in case of an emergency?
|
||||||
| B.7.5* | Do the suites include sufficient
space around furniture to allow persons using mobility aids to move around
easily? (e.g. minimum of 3'-6" (1065mm)) |
Remove extraneous chairs to increase clear space. | |||||
| B.7.6* | In accessible rooms or suites
are all interior spaces (e.g. living room, sleeping area, balcony, kitchen)
connected by an accessible route? |
||||||
| B.7.7* | Where a kitchen or kitchenette
is provided in accessible suites, is there at least one counter/sink and
lowered cabinet suitable for use by persons using wheelchairs? |
||||||
| B.7.8 | Is the kitchen or bar refrigerator
at a suitable height for persons using wheelchairs? |
||||||
| B.7.9* | In an accessible kitchenette are
the faucets and cupboard hardware easy to use by persons with manual limitations?
|
||||||
| B.7.10* | Where coat closets or other storage
units are provided for personal belongings, is the coat rod, hook or shelving,
reachable from a wheelchair (i.e. no higher than 4'-6" (1370mm)? |
||||||
| B.7.11 | Is there at least at least 5'-0"
(1525mm) clear floor space in front of coat closets or other storage units,
for easy access by persons using wheelchairs? |
||||||
| B.7.12 | Is the top of the mattress on
the bed located between 16" and 18" (405mm and 460mm) from the
floor, so that persons using wheelchairs can easily transfer from one to
the other? |
||||||
| B.7.13 | Are table or standard lamps sturdy
and of the touch-type, so that persons with limited reach or dexterity can
put them on/off easily? |
||||||
| B.7.14 | Where a table or desk has been
provided, is there knee clearance of at least 2'-6" (760mm) wide by
2'-3" (685mm) high, so that a person using a wheelchair can use them?
|
||||||
| B.7.15 | Is there sufficient space available
within the suite for any special equipment required by a guest with a disability
e.g. an extra wheelchair, a hoyer lift or other transfer device? |
||||||
| B.8 | Accessible Suite Powder Rooms and Bathrooms | |
|||||
| B.8.1* | Is there a minimum 5'-0"
by 5'-0" (1525mm by 1525mm) clear floor space in accessible washrooms
or bathrooms, for persons using wheelchairs to manoeuvre? |
||||||
| B.8.2 | Are the finished seat heights
of accessible toilets mounted between 16½" and 17½" (420mm and
445mm) from the floor, to allow easy transfers? |
Provide adjustable riser seats for toilets. | |||||
| B.8.3 | Where flush valves are used on
toilets, has a seat cover been included on the toilet, so that it can be
used as a back rest? |
||||||
| B.8.4* | Has clear floor space at least
2'-6" wide (760mm) been provided beside each accessible toilet? |
||||||
| B.8.5* | Are suitable grab rails provided
beside and behind all accessible toilets? |
||||||
| B.8.6 | In accessible washrooms or bathrooms
is there a coat hook which is reachable by persons using wheelchairs (i.e.
no higher than 4'-0" (1220mm) from the floor)? |
||||||
| B.8.7* | In accessible washrooms or bathrooms,
are all accessories (e.g. towel racks, toilet paper holder and tissue dispenser)
accessible to, and useable by, persons in wheelchairs (i.e. with useable
components no higher than 4'-0" (1220mm) from the floor)? |
||||||
| B.8.8 | Is there at least 2'-3½"
(700mm) knee/thigh clearance below accessible washbasins, vanities or sinks,
for use by persons using wheelchairs? |
||||||
| B.8.9 | Is there a clear floor space of
at least 2'-6" wide (760mm) by 4'-0" deep (1220mm) in front or beside each accessible basin, sink or vanity? |
||||||
| B.8.10 | In accessible washrooms or bathrooms,
are mirrors mounted with the bottom edge no higher than 3'-4" (1015mm)
from the floor? |
||||||
| B.8.11* | Have easy to use lever handled
faucets (single action or automatic faucets) been provided on all basins,
sinks, bathtubs or showers? |
||||||
| B.8.12 | Have temperature controls been
provided on all hot water supply sources to minimize accidental scalding?
(e.g. basins, bathtubs, and showers) |
||||||
| B. 8.13 | Is there sufficient storage space
in the accessible bathroom for any special bathing and toileting supplies,
required by a guest with a disability? |
||||||
| B.8.14 | Where a transfer seat is not provided
at the bath head, is a sturdy portable seat available? |
Provide a washable commode-type chair. | |||||
| B.8.15 | Are floor finishes in the bathroom,
shower stall or powder room, non-slip and non-glare? |
Non-slip bath mats. | |||||
| B.9 | Accessible Suite Showers | |
|||||
| B.9.1* | In at least one accessible suite,
has a roll-in shower of at least 3'-0" deep by 5'-0" wide (915mm
by 1525mm) been provided for persons using wheelchairs (in hotels of more
than 50 rooms)? |
||||||
| B.9.2 | Is there a clear approach space
in front of the roll-in shower of at least 3'-0" by 5'-0" (915mm
by 1525mm)? |
||||||
| B.9.3 | Has a moveable or drop-down seat
been provided at one end of the roll-in shower within easy reach of the
shower controls? |
||||||
| B.9.4 | In roll-in showers, are the faucet
handles and controls mounted no higher than 4'-0" (1220mm)? |
||||||
| B.9.5 | Are shower controls easy to use
with one hand, without twisting of the wrist? |
||||||
| B.9.6* | Is the shower head mounted on
a flexible hose, capable of being adjusted in height? |
||||||
| B.9.7 | Is the flexible hose at least
5'-0" (1525mm) long? |
||||||
| B.9.8 | Have horizontal and vertical grab
bars been provided within reach of the seated person and close to the controls?
|
||||||
| B.9.9 | Are horizontal grab bars at least
3'-0" (915 mm) long, mounted on the long wall of the shower, approximately
2'-9" (840 mm) from the floor? |
||||||
| B.9.10 | Have at least 2 recessed soap
dishes been provided, one reachable from the shower seat and one from a
standing position? |
||||||
| B.9.11 | Are all showers equipped with
temperature controls, to ensure that hot water temperature does not exceed
44ºC (110ºF)? |
||||||
| B.10 | Controls and Operating Mechanisms | |
|||||
| B.10.1 | Are television controls easy to
reach by wheelchair users, i.e. mounted no higher than 4'-0" (1220
mm)? |
Provide a remote control with easy to read numbers and letters. | |||||
| B.10.2 | |||||||